1.46 - 161212

12. December 2016

Normal Update

Added Features

  • #3066: Attachment of UPS-Alert-History and Sensor-Logfile for eMails
  • #3184: Display of job timing event to overview column 'when'
  • #2916: Display of IP-Address and MAC-Address in BACS Screen of UNMS
  • #2684: Display of Rescue-Jumper setting for CS141MINI, CS141DMINI, CS141_R2
  • #3211, #2852: Improved wording and Layout of job editor options
  • #3178: Sync of RTC hardware in case system time is set manually
  • #3144: Verify of event job timing configuration during Fw-Update
  • Apply of BACS battery installation date when using IE web browser
  • #2801, #3215: Device added for AS400 connector on com3, AUX is now enabled/disabled thru new com3 mode
  • Preserve admin SFTP password in case of fw-update without reset

Changed Functionality

  • #3209: Improved frontend interpretation of backend error messages
  • #3210: Renamed menu item "Timeserver" to "Date & Time" and moved it under "System",
  • Renamed menu item "HTTP/SSH" to "Webserver" and moved it under "System",
  • Removed config options to enable/disable "SSH" and "SFTP" services,
  • Moved config option to enable/disable "UNMS Server" to "System"."General"
  • Moved config option to enable/disable "Auto Logout" to "System"."Webserver"

Bug Fixes

  • #3217: Major bugfix at Event job : timing option "At [x] seconds remaining time" fixed
  • #3190: Automatic use of Eventname in eMails in case subject is empty
  • #3198: False Logging of "BACS GX_R_AUX x Input x High" even if not connected
  • #3185: Fixed "Not reachable" in UNMS for following UPS protocols: $$GEDELTA, $$MDELTA, $$INFINITY, $$MGE, $$SENTR, $$SENT2, $$KLEIN1, $$GKWR1, $$GKWR3, $$GKUPS1, $$GKUPS3, $$GKNOCARD
  • #3218: Configuration of subject for email-traps and using email-trap intervall on alarms only if event has anti-event

OEM customer specific features, changes and fixes

  • PILLER: UPS monitor screen modifications for "UNIBLOCK UBR III" (#3195),
    • New images for "APOJET S II", "APOJET R II", "APOJET T II" (#3179),
    • Acknowledge of UPS internal event list items (#2988),
    • Switching powerbar on monitor screen with FF for "UBT IV" (#3002),
    • Visualization in monitor screen with FF for "UNIBLOCK UBT IV" (#3015),
    • Visualization of LED's in monitor screen for "APOTRANS II" (#3038),
    • Scrolling thru values in monitor screen for "APOTRANS II" (#3038)
  • CONTROLLED POWER: UPS function screen modifications for "EON" UPS (#3180), UPS load calculation for various "LT" UPS models changed(#3028)
  • AGIT: Screen Modifications for $$XONL12B UPS protocol(#3126)
  • LEGRAND: Logging of “Battery test result: Success” for $$ECONT/2 (#3116), Logging of “Full Test:
    • Holdtime x Min.” for $$ECONT/2 (#3116), Display of 'custom test' function button for $$ECONT/2 (#3115)
    • Swapped page for "UPS Alert History" for protocol $$TRIMOD (#3111)
  • ABB: Switch module views in UNMS for UPS protocol $$CONCE (#3148)
  • ASTRID OEM 70: Visualization in case of TRI-MONO / TRI-TRI for protocol $$EVO2 (#3189).
    • Correctdion for UPS Type 9 Display Triphase in / one Phase out
  • CET: Display of DataLog and Datalog-Chart for UPS protocol $$CET (#3159),
    • Display of "Info"-Buttons for UPS protocol $$CET, "TSI System" (#3157),
    • Visualization of AC-Output in case AC-Input is off for protocol $$CET (#3158),
    • Module info via SNMP in case modules are removed for $$CET, “TSI System" (#3157)
  • OEM ID 12: Added "THYCON UPS" model, added Ablerex Mars II, added EATON 9PX series
  • MULTIMATIC: Added HUAWEI UPS to modellist, added MD-xxxxRT series (MD_1000RT to MDO3000RT), added EATON 9PX series
  • KESS: Added "BatteryX TX301", Missing output voltage for $$MC115 (#3099), added EATON 9PX series
  • DSR: Screenchange for SALISEC protocol for "1.5 kVA Trusted UPS" and "3.0 kVA Tactical UPS"
  • EATON: added EATON 9PX series
  • SECOMP/ROLINE: added EATON 9PX series
  • MGE: MGESHUT protocol implementation improved, more tolerant than previous versions (#3129)
  • DFM SELECT and all other customers using RIELLO/AROS SENTRY protocol: UNMS triggered "not reachable" alarm at this model, fixed with this firmware (#3185)
    -ELINEX: Added Transferswitch from APC Modell ATS, added EATON 9PX series
  • Power Unlilmited Texas: added EATON 9PX series
  • AMG: added EATON 9PX series
  • PTI: added EATON 9PX series
  • AKI: added EATON 9PX series
  • SBS: added EATON 9PX series
  • CANCOM: added EATON 9PX series
  • GENESYS: added EATON 9PX series
  • ADPOS: Missing output voltage for $$MC115 and other UPS protocols (#3099)
  • DSR: Function page modifications for UPS protocol $$SALISEC (#3169)
  • CENTIEL: Parallel handing for Status bit (#3202), Timestamp in "UPS Alert History" now based on year 2000 (#3200)

1.44 - 161123

23. November 2016

Normal Update

Added Features

  • #2741: Added Sensor log and chart for SMTCOM, SMTHCOM and SENSORMANAGER
  • #2993: Added Modbus registers for sensor's
  • #3124: Added SNMP values for sensor's (SM_T_COM, SM_TH_COM, Sensorman)
  • #3168: Validation of manually configured system time
  • #3091: Added Custom configuration option for "Batteries too old"
  • #2987 + #3066: Automatic attachment of "UPS Alert History" stylesheet to EMail Job if the UPS supports this feature.
  • #3132: BACS string name configuration

Changed Functionality

  • #2245 + #2374: UPS Fulltest starts with AutonomyTime 0 and counts down BatteryCapacity

Bug Fixes

  • #2791: AUX configuration was not correctly transferred at firmware update, fixed with this version
  • #3144: Configuration of jobs was not possible using with delays. Fixed with this version
  • #3121: BACS B4 caused a script error message with UNMS and EATONs IPM, fixed with this version
  • #3087: Webpage "Refresh Time" configuration fixed with this version
  • #3103: Wrong hint for "Set System Time Manually"
  • #2996: Display of event job timing for threshold events fixed
  • #3167: "Error 520" when executing “Synchronize CS141 with Timeserver” fixed with this version
  • #3082: Frontend timeout "Error 500" during system time sync with timeserver, but time sync was OK. Timeout now increased.

OEM customer specific features, changes and fixes

  • UPS SERVIS Latvia: First version for this customers, replacing Powertronix ID 30
  • JOVYATLAS/WAERTSILA: Added Jovycube-T4S with protocol WAERTSILA (deviation from CET protocol)
  • AEG: MBCUBE Screen replaced by standard screen, this fixes wrong display of Battery capacity on this UPS
  • SALICRU: MBCUBE Screen replaced by standard screen
  • AGIT: Centralion Inova XONL12B series legend added #3128,
    • Missing SNMP values for UPS protocol $$KSTAR (#3096, \
    • #2877 added UPS Fulltest function for XONL12B, C and D
  • DFM Select and all customers using AROS SENTRY protocol:Increased "communication lost" timeout for UPS protocol $$SENT2. CS141 UPS polling changed to 6 times no correct answer before a communication lost entry is made into CS141 logfile.
  • KSTAR: Customers using KSTAR UPS did have problems with using UNMS with SNMP as communication protocol, fixed with this firmware #3096
  • ABB and LEGRAND: #3153: Message "New firmware available" is now checking against the offical download pages on GENEREX Webserver for OEMs first. If at the OEM page is a "fixed" version, than the system will not display this message, although there is a newer firmware available elsewhere. This feature is active currently for ABB OEM 36 and LEGRAND OEM 8
  • MANNSHARDT: #3138: Display of nominal power for UPS protocol $$PREXT
  • ABB and all customers using ABB OEM products: #3182 Event 'UPSMAN started' was not executed for $$CONCE
  • ABB and all customers using ABB OEM products: #3175 Display of available UPS modules for UPS protocol $$CONCE fixed
  • LEGRAND: #3114 Display of nominal power for UPS protocol $$ECONT/$$ECONT2, #3112 Display of "Switch phase On/Off" button for UPS protocol $$TRIMOD
  • PILLER: #2987 Attachment of "UPS Alert History" now configurable manually in EventJobs, #3094 Event evaluation for "UPS Output On/Off" for UPS "AP Premium"
  • ADPOS: #2977 added communication protocol for "Micro Pro V"
  • ONLINE: #2877 added UPS Fulltest function for XONL12B, C and D
  • DRS Technology : #2977 Removed "Auto Restart" and "Shutdown Type" functionality
  • COROMACTIC an all customers using SOCOMEC JBUSP protocol: #3011 Calculation of "Battery Capacity" and "Remaining Time" for $$JBUSP added
  • Multimatic and all customers using ABLEREX UPS with PRABLER2 protocol: #2995 UPS "Toggle Buzzer" function added, #2024 Missing variables for $$PRABLER2

1.42 - 161103

3. November 2016

Normal Update

Added Features

  • #2911: Implementation of CON_AUX4 and it's configuration
  • #3045: Backup/Restore function of CS141 fixed with this version
  • #3072: Add “Trace” Group to "Tools" Page
  • #3050: BACS config options for “List modules stringwise” (NOT FIXED !!)
  • #2024: ABLEREX Transferswitch OEM 012, 017, 045: Ablerex STS Transferswitch added
  • #2689: During "Initialising" phase the RS232 communication can be monitored via Firefox, Chrome or Safari Webbrowser at URL "http:///trace/ups"
  • #3081: CS141 with CONAUX4 or CONRAUX4 or SENSORMANAGER supports now Alarmmanagement with UNMS software

Bug Fixes

  • #3083:(and subtickets #3099,#3089)UNMS shows "communication lost" at CS141 alarmstatus. Fixed with this version. (UNMS update required)
  • #2864:(and #3118) Timeserver switches back to Greenwich after update, UPS time sync error is suppressed for manually time setting, added Timezones with DST (if available)
  • #2964: Issue with passwords containing special characters fixed
  • #3120: Missing BACS flag registers in modbus
  • #3044: Email Traps transmitted empty subjects
  • #2822: UPS Alert History is hidden if UPS does not support this feature
  • #2991: Datalogentries -9999, now showing not available DataLog entries as "n/a"
  • #3089: UNMS unreachable problem solved with this version
  • #2969: BACS Programmer minor fixes
  • #3000: Q-Script Error for SNMP_CODE with Pnnnx Variables could cause missing values in SNMP requests for upsBatteryStatus, upsEstimatedMinutesRemaining, upsBatteryTemperature, and other values. Fixed with this version
  • #3090: Emailconfiguration was not cleared at a firmware factory reset, fixed with this version
  • #3083: False alarms from CS141 at configuration changes fixed
  • #2976: CS141 LED activation for device communications lost, red led is shown for missing communication for any connected devices
  • #3054: MessageBox after update automatically closes
  • #3057: - “Reset to factory” is set when updating other OEM
  • #3067: BACS minor differences between CS121 based BACS and CS141 based BACS SNMP Walk eliminated
  • #3105: Modbus/IP Slave ID configuration fixed in this version

OEM customer specific features, changes and fixes

  • MULTIMATIC ID 17: Added MD-6000T series
  • SOCOMEC ID 77: Download for Software enabled
  • SICOTEC ID 78: UPS modellist clean up - removed all older UPS models (NOTE: This may cause loosing configurations when updating from older devices to this version)
  • GKLEIN ID 62: #3088 Fix for serial communication for $$KLEIN1
  • PILLER ID 3: #3030 Batterietemp. fix for UNIBLOCK UBT IV, Missing events for "UNIBLOCK UBT IV",
    • #3017: added data at SNMP Walk for UNIBLOCK UBT IV, #3003 change offset to +167
  • BENNING ID 19: #2999, added BENMOD Enertronic L 3-3 missing SNMP values, SNMP load zero value for $$PILMOD/$$BENMOD
  • LEGRAND ID 8: #3060 KEOR T - Auto Restart removed at Functions Page and changed visibility of output switches for TRIMOD
  • EFFEKTA ID 32: #3020 EFFEKTA MKD 1000 RT XL, $$XONL12D, Load > 80/90% logging now fixed
  • All OEMs using CENTRALION GRIPOWER: (AEG, Riello Multi Guard GMT and others) #2914, #2933 Logging of faults and warnings
  • ADPOS ID 87: #3093 Added "Micro Pro V" with $$WOEHRLE as protocol
  • ASTRID ID 38 : EVO Time Sync now OK with this version
  • AGIT ID 99: UPS-Alert-History Modifications for $$XONL12B, ETXL modelnames changes
  • PIVITOL Power ID 20: 1.5kVA and 3.0 kVA UPS with SALISEC protocol has a new screen
  • ABB: Removed unsupported baudrates from setup ABB OEM 036 CONCE protocol