Added Features
- BACS Device now optional for all CS141 devices with AUX/COM3 [T90/#3288].
- This firmware changes every CS141L, SC, LM, SCM into a full qualified BACS WEBMANAGER by simply adding the BACS Busconverter and the BACS Modules
- UPS Custom Threshold Events added [T409/#2885]
- Watchdog OS added with Timer 5 minutes [T3009]
- Trace Network (TCP Dump) via User Interface [T3022]
Changed Functionality
- User interface changes: Replaced page titles above each page.
- Moved options to en-/disable devices to new page 'Devices > General.
- Provide uniform design and consistent structure on all dialogs.
- Provide uniform design and consistent structure on all configuration pages.
- Input timing parameters for all EVENT jobs increased [T89/#3289]
Bug Fixes
- Allow backend more time to shutdown on reboot [T3024]
- Inconsistency in Date & Time formatting for display [T2971]
- After 1 year the uptime begins with 0 days, fixed with this version
- Event-Logic GX_R_AUX Inputs vice-versa, fixed with this version [T2995]
- AUX SNMP Traps added [T2960]
- BACSKIT reboots if system time is decreased [T3046], fixed with this version
- Event-Job Testbuttons display issues, fixed with this version [T2914]
- AUX configuration was not transferred at firmware updates, fixed with this version [T2998]
- BACS String Names configuration issues fixed [T2996]
- Login as 'engineer' o. 'guest' showed false menues, fixed with this version [T2973]
- SNMP Trap 'upsTrapOnBattery' is not repeated in 1 minute intervals [T3026]
- Missing menue SensorLog(Chart) on COM2 fixed [T2988]
- Backend (gxserve) hang up at overrun UPSTCP connections solved [T3016]
- Testing command recognition of job 'RCCMD Execute' fixed [T2983]
- Uptime in Aboutbox refresh fixed (Regression since 1.59) [T3008]
OEM customer specific features, changes and fixes
- SBS EQUALINK: Display-Names for device and services / Equalink SBS OEM ID 69 [T2/#3410]
- ONLINE: Minor changes on new "ZINTO 800 - 3000 VA (Mod.2017)" [T2929]
- Implementation of new "XANTO 6000 - 20000 VA (Mod.2017)" [T2853]
- Implementation of a new UPS series "Voltronic NANO" as YUNTO Q 2017 [T2987]
- Bugfix XONL12A - false alarm at SNMP Variable upsAlarmWarningStatus [#3316]
- OEM 070: Minor changes on new UPS-Protokoll UPS Type 12 einbinden [T2908]
- WOEHRLE: Ablerex TAURUS MODBUS protocol MBTAURUS, Disable UPS OFF signal [T359/#2958]
- AEG: Protect 3. M GRIPOW Output Current now corrected in UPS Screen [T2886]
- Protect Plus M600 INVT/MBSALIRM Colors changed at 'On Battery' [T2921]
- Protect Plus M600 INVT/MBSALIRM correcte AutonomyTime Display after Batterytest [T2920]
- UPS Functionsscreens now visible again (hidden in FW 1.58) [T3005]
- Protect Blue ($$CBSR4): Displayfix of Total Overview page [T2979]
- PILLER : APOTRANS II values unsigned u. switching voltage problem fixed [T296/#3035]
- AP Premium Adapter-Events [#3403] T9 & T296
- Bugfix APOTRANS_III Events logic [T2874]
- Screen bugfixes UBT_IV [T2902]
- Date/Time UPS synchronization [3018]
- APOTRANS III Page Power - Powerfactor [T2917]
- APOTRANS III Page ENERGY Meter bugfix [T3020] and [T2915]
- APOTRANS III Page Power - Apparent Power Anzeige [T2916]
- APOTRANS III Page MAINS2 and LOAD - Display P-P Values [T2919]
- APOTRANS II - Switching screen bugfixes [T47/#3356]
- UBT_IV - Dump 41 - Screenadjustments [T2965]
- UBT_IV - Dump 42 - Screenadjustments [T2966]
- UBT_IV - Dump 35 – Screenadjustments [T2967]
- APOTRANS III Page MAINS1, MAINS2 and LOAD display "neutral current" fixed [T2918]
- $$PILMODxx: Write command at MODBUS Address 1 implemented [T45/#3358]
- LEGRAND: Megaline ECONT2 Device Functions corrected [T2925]
- TRIMOD Power Modules, Misc Data, Inverter/Booster Temperatures corrected [T2945]
- DK Plus series added with 9600 baud as default [T1830]
- TRIMOD load display over 100% causes wrong autonomytime, corrected [T2942]
- Bugfix for TRIMOD in UNMS, now working with UPSTCP and with SNMP RFC 1628 [T2954]
- ABB: CONCE Alarm Input Bad (XID 618) added to MODBUS Address 120 [T76/#3309]
- SNMP upsAlarmDescriptionID counter corrected [T2922]
- Fix at CONCE for Modbus address 167 Total battery current, shows now the values of all modules in the multidrop bus [T3037]
- CENTIEL: UPS Events (History) Handling [ID: 10] [T152/#3204]
- Modbus Registers 111…113 changed to 0.1Hz [T2984/ID:79]
- Added 2 new Modbus-Register for 'Inverters Supplying the Load' (ISL) [T2985/ID:83]
- ALTERVAC: AETSER via UPS Functions initiated shutdown/restore now fixed [T2906]
- AGIT: KSTAR (Agpower ETX 10-500kVA Modbus) wrong status displayed without batteries, corrected [T2894]
- $$XONL12C: Custom Screen for Agpower C RT 1-10kVA' [T36/#3370]
- $$XONL12B: Custom Screen for 'Agpower D T 10-20kVA' [T218/#3125]
- COROMATIC: Added new UPS models "JBUS Modulys", "JBUS Delphys MX/MP", "JBUS Delphys BC", "JBUS Statys" [T481/#2779]
- SALICRU: Added Transferswitches "SPS 16 ATS", "SPS 32 ATS" with protocol STSABLER
- Added modular values on INVT/ADAPT-X UPS
- Added SLC-TWIN PRO2 and RT2 series
- SLC TWIN PRO2 <=3kVA ($$ZINTOE), Change UPS command for Battery Voltage [T2981] and fix at Device Functions [T2978]
- KESS: batterX Hybrid USV Implementierung [T256/#3086]
- SNG: New OEM SNG Australia as OEM ID 77, first OEM version 77 release
- MULTIMATIC: Added "MD-XSerie 60-125kVA"
- Fix for EDELSTROM Functions with $$PRABLER2 Restore UPS command [T2911]
- PowerControl UK: New OEM Powercontrol OEM ID 74, first OEM version 74 release
- KESS: Battery X T256/#3086 fixed
- EATON: MGESHUT at EATON UPS ID319 cause error at UPS functions, fixed
- Eaton 9PX $$MGESHUT Server Error 503 message fixed in UPS model menue [T3028]
- SIEL: Added custom configuration field for user data [T55/#3344]
- EFFEKTA: Added CENTRALION Transferswitch as EFFEKTA ATS 16 [T2955]
- INVT: Added modular values
- CET: CE+T private MIB f. Model Agil implemented [T441/#2838]
- ASTRID: Added new UPS-Protocol as UPS Type 12 [T2908]
- CENTIEL: UPS Events (History) Handling [ID: 10] [T152/#3204]