1.42 - 161103

3. November 2016

Normal Update

Added Features

  • #2911: Implementation of CON_AUX4 and it's configuration
  • #3045: Backup/Restore function of CS141 fixed with this version
  • #3072: Add “Trace” Group to "Tools" Page
  • #3050: BACS config options for “List modules stringwise” (NOT FIXED !!)
  • #2024: ABLEREX Transferswitch OEM 012, 017, 045: Ablerex STS Transferswitch added
  • #2689: During "Initialising" phase the RS232 communication can be monitored via Firefox, Chrome or Safari Webbrowser at URL "http:///trace/ups"
  • #3081: CS141 with CONAUX4 or CONRAUX4 or SENSORMANAGER supports now Alarmmanagement with UNMS software

Bug Fixes

  • #3083:(and subtickets #3099,#3089)UNMS shows "communication lost" at CS141 alarmstatus. Fixed with this version. (UNMS update required)
  • #2864:(and #3118) Timeserver switches back to Greenwich after update, UPS time sync error is suppressed for manually time setting, added Timezones with DST (if available)
  • #2964: Issue with passwords containing special characters fixed
  • #3120: Missing BACS flag registers in modbus
  • #3044: Email Traps transmitted empty subjects
  • #2822: UPS Alert History is hidden if UPS does not support this feature
  • #2991: Datalogentries -9999, now showing not available DataLog entries as "n/a"
  • #3089: UNMS unreachable problem solved with this version
  • #2969: BACS Programmer minor fixes
  • #3000: Q-Script Error for SNMP_CODE with Pnnnx Variables could cause missing values in SNMP requests for upsBatteryStatus, upsEstimatedMinutesRemaining, upsBatteryTemperature, and other values. Fixed with this version
  • #3090: Emailconfiguration was not cleared at a firmware factory reset, fixed with this version
  • #3083: False alarms from CS141 at configuration changes fixed
  • #2976: CS141 LED activation for device communications lost, red led is shown for missing communication for any connected devices
  • #3054: MessageBox after update automatically closes
  • #3057: - “Reset to factory” is set when updating other OEM
  • #3067: BACS minor differences between CS121 based BACS and CS141 based BACS SNMP Walk eliminated
  • #3105: Modbus/IP Slave ID configuration fixed in this version

OEM customer specific features, changes and fixes

  • MULTIMATIC ID 17: Added MD-6000T series
  • SOCOMEC ID 77: Download for Software enabled
  • SICOTEC ID 78: UPS modellist clean up - removed all older UPS models (NOTE: This may cause loosing configurations when updating from older devices to this version)
  • GKLEIN ID 62: #3088 Fix for serial communication for $$KLEIN1
  • PILLER ID 3: #3030 Batterietemp. fix for UNIBLOCK UBT IV, Missing events for "UNIBLOCK UBT IV",
    • #3017: added data at SNMP Walk for UNIBLOCK UBT IV, #3003 change offset to +167
  • BENNING ID 19: #2999, added BENMOD Enertronic L 3-3 missing SNMP values, SNMP load zero value for $$PILMOD/$$BENMOD
  • LEGRAND ID 8: #3060 KEOR T - Auto Restart removed at Functions Page and changed visibility of output switches for TRIMOD
  • EFFEKTA ID 32: #3020 EFFEKTA MKD 1000 RT XL, $$XONL12D, Load > 80/90% logging now fixed
  • All OEMs using CENTRALION GRIPOWER: (AEG, Riello Multi Guard GMT and others) #2914, #2933 Logging of faults and warnings
  • ADPOS ID 87: #3093 Added "Micro Pro V" with $$WOEHRLE as protocol
  • ASTRID ID 38 : EVO Time Sync now OK with this version
  • AGIT ID 99: UPS-Alert-History Modifications for $$XONL12B, ETXL modelnames changes
  • PIVITOL Power ID 20: 1.5kVA and 3.0 kVA UPS with SALISEC protocol has a new screen
  • ABB: Removed unsupported baudrates from setup ABB OEM 036 CONCE protocol

1.40 - 161011

11. October 2016

Normal Update

Added Features

  • #3027: Missing SNMP system variables added, BACS value scaling / decimal points for SNMP variables
  • #3067: BACS SNMP values added 2 digits after comma for all variables
  • #3053: BACS Discharge Detection Source for “UPS” added
  • #3023: BACS Modul Temp & Impedance Offse added
  • #3072: Tracing tool for UPS COM1 communication added, RS232 low level implementation redesigned to optmized port sharing between COM1-COM3
  • #3057 + #3054: MessageBox after update automatically closes and “Reset to factory” is set automatically when updating other OEM

Bug Fixes

  • #3051: SENSORMANAGER looses configuration after firmware update, fixed with this version
  • #2871: Fix for GSM modem timeouts for RS232 ( connected to COM2 ), solves issues with GSM in earlier versions
  • Serial port resource conflicts fixed with this version
  • Possible damage of IP configuration by UPS time sync if power loss during this step
  • #2966 Modbus ID bug solved with this version

OEM customer specific features, changes and fixes

  • CENTIEL: Added system battery voltage and Improvement of $$CENTIEL protocol implementation
  • BORRI/ASTRID: #2972: UPS Type 11, Borri neutral (OEM 70), Problems mit Strings, Clock, Internationalization of UPS alert history
  • PILLER: PB decimal places for "UNIBLOCK UBT IV", "UNIBLOCK UBT IV" screen switches in Firefox, Batt.-Temp decimal places for "UNIBLOCK UBT IV",
    • #3017: SNMP missing data at SNMP Walk UNIBLOCK UBT IV
    • #3002: UBT IV Change Screen Load columns
    • #3029: Powerbridge (PB) Remaining Time
    • #3030: Batterietemperature correction in Display for UNIBLOCK UBT IV
  • LEGRAND: #3061 Visibility of output switches for $$TRIMOD, #3061 Removed Custom-Test for $$ECONT, commands Fulltest,
    • #3061 Cancel-Shutdown, Switch-Bypass/Online,
    • #3060 Removed Auto-Restart for $$PRPYRDSP, Added "KEOR HPE" series with protocol EVO4
  • S2S OEM 047: #3041: Modbus requests/responses for $$TRIMOD fixed
  • ONLINE:Custom function screen for $$XONL, Custom function screen for $$ZINTOE
  • CONTROLLED POWER NETMINDER: #3028 Using battery capacity from UPS for $$CPUSA2 and $$CPUSA3
  • BENNING: #2999 BENMOD, Enertronic L 3-3, missing SNMP Output-Load
  • ABB OEM 036: (Not Ticket) Unsupported OS RS232 baudrates for $$CONCE removed.
    • #2696: Fixed Display UPSVIEW at Conce protocol at UPS Status "UPS Shutdown/System Off", now shown as "red"
  • MANNSHARDT: #3046 Protocol implmentation PREXT (VOLTRONIC)changed, Shutdown/Restore no longer used, instead "Shutdown with Duration" to avoid a known hardware problem with this UPS model at power restored.
  • EFFEKTA: #3020 and #2996 MKD 1000 RT XL, $$XONL12D, Load > 80/90% looging problem fixed
  • All customers using ABLEREX MSRT and compatibles #2995:: New custom function screen for these UPS models with swithing outlet buttons
  • All customers using ABLEREX Transferswitch STS: New custom function screen for these Transferswitches
  • AKKUTRONIK: Added "X-Plus TE series" from ABLEREX with MBTAURUS modbus protocol
  • TRANSFERSWITCHES from RIELLO: (Riello Multiswitch ATS) Fixes in SNMP data
  • WAERTSILA/JOVYATLAS: #2849 Added JOVYCUBE with "WAERTSILA" protocol as subversion from CET protocol
  • ASTRID/BORRI:#2972 and #3013 Astrid Time sync fix and Eventrecorder fix
  • ELINEX: Added GE LP and SG series
  • AGIT: First version for OEM ID 99 AGIT Poland
  • STACO Energy USA ID 94: Protocol change for "Firstline PL/PLT" to SALISEC

1.38 - 160927

27. September 2016

Normal Update

Added Features

  • First version with support for BACS WEBMANAGER 4
  • SNMP B-2 subtree added

Bug Fixes

  • BACS B4 is now triggering General Alarm in case RI values are out of range of sensors (This was not
    the case in earliere BACS systems, here a "n/a" at RI did not cause a General Alarm. Changed with this
    version.
  • #2972 + #3012 Time sync for all UPS makers protocols aligned to the same code
  • #2426: Datalog and Datalogchart had a wonrg timestamp, fixed now in UTC format. One hour time shift fixed

OEM customer specific features, changes and fixes

  • BORRI/ASTRID: #2972 EVO Type 11 issues with internal clock sync and internal black box fixed
  • PILLER: #3003: UBT IV Messwert Operation Hours
    • #2987: Attaching PILLER Eventrcorder to Emails
    • #3005: added Modbus-Adress 999 for Status "Communication lost"
    • #2985: added webpage for device specific functions
    • #2935: added email transmission through PILLER Gateway
  • LEGRAND: #2963 + #3008 Several fixex for Trimod, including Clock Sync
  • WAERTSILA/JOVYATLAS: #2849 added new UPS protocol for "Waertsila MODBUS" for JOVYCUBE
  • MANNSHARDT: #2787 Enhancements for VOLTRONIC protocol PREXT