1.40 - 161011

11. October 2016

Normal Update

Added Features

  • #3027: Missing SNMP system variables added, BACS value scaling / decimal points for SNMP variables
  • #3067: BACS SNMP values added 2 digits after comma for all variables
  • #3053: BACS Discharge Detection Source for “UPS” added
  • #3023: BACS Modul Temp & Impedance Offse added
  • #3072: Tracing tool for UPS COM1 communication added, RS232 low level implementation redesigned to optmized port sharing between COM1-COM3
  • #3057 + #3054: MessageBox after update automatically closes and “Reset to factory” is set automatically when updating other OEM

Bug Fixes

  • #3051: SENSORMANAGER looses configuration after firmware update, fixed with this version
  • #2871: Fix for GSM modem timeouts for RS232 ( connected to COM2 ), solves issues with GSM in earlier versions
  • Serial port resource conflicts fixed with this version
  • Possible damage of IP configuration by UPS time sync if power loss during this step
  • #2966 Modbus ID bug solved with this version

OEM customer specific features, changes and fixes

  • CENTIEL: Added system battery voltage and Improvement of $$CENTIEL protocol implementation
  • BORRI/ASTRID: #2972: UPS Type 11, Borri neutral (OEM 70), Problems mit Strings, Clock, Internationalization of UPS alert history
  • PILLER: PB decimal places for "UNIBLOCK UBT IV", "UNIBLOCK UBT IV" screen switches in Firefox, Batt.-Temp decimal places for "UNIBLOCK UBT IV",
    • #3017: SNMP missing data at SNMP Walk UNIBLOCK UBT IV
    • #3002: UBT IV Change Screen Load columns
    • #3029: Powerbridge (PB) Remaining Time
    • #3030: Batterietemperature correction in Display for UNIBLOCK UBT IV
  • LEGRAND: #3061 Visibility of output switches for $$TRIMOD, #3061 Removed Custom-Test for $$ECONT, commands Fulltest,
    • #3061 Cancel-Shutdown, Switch-Bypass/Online,
    • #3060 Removed Auto-Restart for $$PRPYRDSP, Added "KEOR HPE" series with protocol EVO4
  • S2S OEM 047: #3041: Modbus requests/responses for $$TRIMOD fixed
  • ONLINE:Custom function screen for $$XONL, Custom function screen for $$ZINTOE
  • CONTROLLED POWER NETMINDER: #3028 Using battery capacity from UPS for $$CPUSA2 and $$CPUSA3
  • BENNING: #2999 BENMOD, Enertronic L 3-3, missing SNMP Output-Load
  • ABB OEM 036: (Not Ticket) Unsupported OS RS232 baudrates for $$CONCE removed.
    • #2696: Fixed Display UPSVIEW at Conce protocol at UPS Status "UPS Shutdown/System Off", now shown as "red"
  • MANNSHARDT: #3046 Protocol implmentation PREXT (VOLTRONIC)changed, Shutdown/Restore no longer used, instead "Shutdown with Duration" to avoid a known hardware problem with this UPS model at power restored.
  • EFFEKTA: #3020 and #2996 MKD 1000 RT XL, $$XONL12D, Load > 80/90% looging problem fixed
  • All customers using ABLEREX MSRT and compatibles #2995:: New custom function screen for these UPS models with swithing outlet buttons
  • All customers using ABLEREX Transferswitch STS: New custom function screen for these Transferswitches
  • AKKUTRONIK: Added "X-Plus TE series" from ABLEREX with MBTAURUS modbus protocol
  • TRANSFERSWITCHES from RIELLO: (Riello Multiswitch ATS) Fixes in SNMP data
  • WAERTSILA/JOVYATLAS: #2849 Added JOVYCUBE with "WAERTSILA" protocol as subversion from CET protocol
  • ASTRID/BORRI:#2972 and #3013 Astrid Time sync fix and Eventrecorder fix
  • ELINEX: Added GE LP and SG series
  • AGIT: First version for OEM ID 99 AGIT Poland
  • STACO Energy USA ID 94: Protocol change for "Firstline PL/PLT" to SALISEC

1.38 - 160927

27. September 2016

Normal Update

Added Features

  • First version with support for BACS WEBMANAGER 4
  • SNMP B-2 subtree added

Bug Fixes

  • BACS B4 is now triggering General Alarm in case RI values are out of range of sensors (This was not
    the case in earliere BACS systems, here a "n/a" at RI did not cause a General Alarm. Changed with this
    version.
  • #2972 + #3012 Time sync for all UPS makers protocols aligned to the same code
  • #2426: Datalog and Datalogchart had a wonrg timestamp, fixed now in UTC format. One hour time shift fixed

OEM customer specific features, changes and fixes

  • BORRI/ASTRID: #2972 EVO Type 11 issues with internal clock sync and internal black box fixed
  • PILLER: #3003: UBT IV Messwert Operation Hours
    • #2987: Attaching PILLER Eventrcorder to Emails
    • #3005: added Modbus-Adress 999 for Status "Communication lost"
    • #2985: added webpage for device specific functions
    • #2935: added email transmission through PILLER Gateway
  • LEGRAND: #2963 + #3008 Several fixex for Trimod, including Clock Sync
  • WAERTSILA/JOVYATLAS: #2849 added new UPS protocol for "Waertsila MODBUS" for JOVYCUBE
  • MANNSHARDT: #2787 Enhancements for VOLTRONIC protocol PREXT

1.36 - 160830

30. August 2016

Normal Update

Added Features

  • #2998:Start of SNMP service at system boot
  • Modbus RS-232/RS-485 performance, faster response than previous versions
  • #2966: Modbus communication with multiple masters
  • #2895: Refresh Buttons für EventLog and DataLog and RCCMD Certificates

Bug Fixes

  • #2930: Switch outlet buttons for $$PRABLER2 caused error 420
  • #2990: Network DIP Switch on CS141R_2 hardware
  • #2467: Logging "Log files rotated" only for AlarmLog
  • #2847: SENSORMANAGER fixes for alarm thresholds
  • #2978: Bugfix for FW 1.32 "Memory Leak in AUXDevice::GetData(...)Backend gxserve v0.2.04 at CS141 with sensors connected
  • #2992: Internals logging from SNMPd disabled

OEM customer specific features, changes and fixes

  • AEG: Disabled UPS On/Off functions for $$CBSRn
  • AEG: Limited UPS event history to 50 items for $$CBSRn
  • AEG: #2973: Protect B (AEG, OEM 2), FW 1.32, fehlerhafte Kommunikation
  • PILLER: Modbus Mapping of UPS registers
  • PILLER: Modbus write commands for UPS registers
  • PILLER: Pages/Screens for UPS specific functions
  • PILLER: Acknowledge function for UPS event history items
  • PILLER: UTF-8 encoding of UPS event history
  • PILLER: AR Comfort added UPs Alert history ($$SENTRY and related)
  • PILLER: #2891: IP-switching via PILLER Gateway CS141DMINI
  • PILLER: #2932: internal Pull-Down resistors now configurable per SW
  • PILLER: #2984: Piller (oem3): Illegal Data Address
  • PILLER: #2986: Special characters cause „Parser Error“ in event text
  • PILLER: #2988: Acknowledge of Event text
  • PILLER: #2985: Missing specific "devicefunctions"
  • PILLER: #2989: Write commands Modbus TCP implemented
  • CENTIEL: Implementation of "Centiel UPS"
  • EFFEKTA: Removed UPS models ""EFFEKTA MKD 700 RM RT" up to 3000 RM RT and added "EFFEKTA MKD 1000 RT XL" series up to 3000
  • EFFEKTA: Changed MKD RT series protocol from AETSER to XONL12D
  • EFFEKTA: Logo changed
  • WISAG: Removed as OEM ID 20 and replaced by PIVITOL POWER
  • PIVITOL Power: New OEM ID 20