1.54 - 170405

5. April 2017

Normal Update

Added Features

  • Timeserver tests are now returning a result in the CS141 logfile
  • First version supporting CS141 BUZZER as AUX device T506/#2747

Changed Functionality

  • Text adjustments in german language mode T157/#3199 and french T41/#3363

Bug Fixes

  • "Optimized Scan" button fixed T29/#3379
  • Shutdown RCCMD signal changed for AS400/iSeries compliance, fixed with this version #3385
  • Fahrenheit / Celsius configuration fixed on all UPs screens T405/#2890
  • Webserver frontend timeout increased to avoid error messages "<503> backend busy”
  • Bugfix on BACS Programmer Webpage in CS141/B4 T2865

OEM customer specific features, changes and fixes

  • AEG: Modelname Protect Plus M600 changed, interal Modbus registers now transferred to Modbus over IP #3304
  • ADPOS: Energycounter added to Sensormanager T114/#3253
  • ABB all : Emailtrap configuration changed to notify the user about missing input T13/#3397,
    $$CONCE, Timeserver - UPS Time Synchronisation did not work correct, fixed with this version T1/#3412
  • ABB ID36: SSB project - #3407 - Protocol CONCE, backend hangup fixed when only 1 input line found (upsdev v1078,
    Emailtrap configuration changed to notify the user about missing input T13/#3397
    $$CONCE, Timeserver - UPS Time Synchronisation did not work correct, fixed with this version T1/#3412
    $$CONCE: System measures of disappeared module still visible T18/#3391
  • BORRI/ASTRID: Change log entry at $$EVO2 + $$EVO3 - if ups communication was lost, the log entry if the job "Event System Shutdown2 is logged T1082/#1895
  • EFFEKTA: Changed protocol of EFFEKTA Adira 1/1 6kVA" to $$XONL12C (before CONQ) and EFFEKTA Adira 1/1 10kVA" = $$XONL12C
  • KESS: Changes on BatteryX implementation T256/#3086
  • ONLINE: First firmware supporting new ZINTO 2017 and XANTO 2017 T67/#3022
  • LEGRAND: First version of integration Ablerex DK Plus UPS with JBUSMODULYS protocol #3290 (not finished)
    TRIMOD, TRIMODHE: Fix at SNMP value upsEstimatedMinutes remaining T2861
  • PILLER: Attach UPS alarmlog to Emailjobs added T269/#3066, APOTRANS III Display corrected T46/#3357,
    AP Premium Adapter-Events added T9/#3403
  • CENTIEL: UPS Events (History) display [ID: 11] [T151/#3205] changed, sN display corrected [T153/#3203] and T151/#3205
  • S2S: Added all LEGRAND UPS models
  • DFM Select and all customers using UPS standard screens: Screen change - added 2nd input line #3402
  • all customers using SALISEC protocols (ID 1 and 12): Modbus values extended
  • GRUENCO: Batteryvoltage value for MARS RT 2000 adjusted
  • CONTROLLED POWER: Load display changed at "UltraLITE (240 or 208V in-out)"$$CPUSA T2850

1.52 - 170307

7. March 2017

Normal Update

Added Features

  • Introduction of "Optimized Scan" - this is a fast discharge mode for BACS.
    • Default is now that during a discharge the only the voltages are measured as fast as possible. This mode does no longer measure impedances, temperatures, current is updated in longer intervals than before. BACS VIEWER is now able to show an improved discharge curve. #3379
  • All customers using standard UPS screens: New screen with extra bypass introduced
  • All customers : Added simple UPS monitor screen [#3322]
  • Added AUX event jobs for switching UPS outlets #3373
  • Limit Thermal Runaway Parameter 'TempDiff' added #3278

Changed Functionality

  • Log messages for switching AUX ports improved #3384

Bug Fixes

  • Bugfix for SENSORMANAGER - switching AUX and SENSORMANAGER OUTPUTs did not work, fixed with this versione #3384
  • Some UPS models "Restore configuration" cause a reset to default event jobs, fixed with this version #3383
  • Deactivation of "Automatic Logout" fixed #3381
  • UPSTCP server hangup while rest of system is still running, fixed with this version #3346
  • BACS current sensor displaye "n.a." at discharge between 0-1A (discharge) solved #3317 & #1015

OEM customer specific features, changes and fixes

  • AEG: Protect M600 screenchanges #3360
  • ABB all : Underline AUX module number on monitor screen added #3391
    • Screen shows -9999V on line1 if no any module found on this line, solved #3392
  • ABB ID36: OEM pre-configuration of Email-traps after firmware-update added #3345
    • Module 3 shows measures of non-present module 2 fixed #3388
    • Mains failure on Line 1 doesn't show frequency as zero, fixed #3389 & #3233
    • Frequency interval improved and display at powerfail changed, module lost display changed #3233
  • ERREPI and all other customers using POWERCOM UPS: Fix for BNTUSB function outlet switching #3372, #3371
  • UPS SERVIS: ABLEREX STS wrong log messages fixed #2024
  • WOEHRLE: ABLEREX STS wrong log messages fixed #2024
  • MULTIMATIC: ABLEREX STS wrong log messages fixed #2024
  • KAUFEL: Logo updated #2389
  • COROMATIC and all SOCOMEC users OEM IDs 17,26,28,47,55,66,67,78,96,100: Added ITYS PRO model and
    fix #3254 (Battery failure and General alarm)
  • KESS: Logo updated
  • ONLINE: Added new UPS models 2017 #3022
  • ONLINE: Change at XANTO S screen #2192
  • LEGRAND: Problem with Battery too old message, was executed after 5 month fixed for TRIMOD protocols #3375
  • LEGRAND: SNMP section ECONT changed, added SNMP values for InputTruePower and OutputCurrent #3367
  • ETEC: Added EC series
  • PILLER: Apostar AS 4 in UNMS unreachable, fixed with this version #3364 (Note: latest UNMS software required)
  • PILLER: Monitor screen for "APOTRANS III" #3357
  • CENTIEL: Improved UPS alarm history display speed after boot #3205
  • CET: Missing SNMP traps for $$CET #3161
  • all customers using TOSHIBA SEC 9600b : various alarm issues fixed at $$TOSHIBASEC #3380.
  • all customers using MITSUBISHI 9xx, 2033, 9800 - protocol $$SALISEC replaced by $$TOSHIBASEC

1.50 - 170217

17. February 2017

Normal Update

Added Features

  • Full GX_R_AUX module implementation [#3062]
  • Additional french translations [#3236, #3363]
  • Event jobs for GX_R_AUX and SensorMan devices [#2981]
  • Upgraded frontend framework 'AngularJS' to Version 1.5 [#3348]
  • Added drop down box for voltage difference (#3150)

Changed Functionality

  • Timerange for Eventjob timers increase (#3289)

Bug Fixes

  • Bugfix: "Security engine ID" for SNMPv3 was not static [#3297]
  • Bugfix: Menu labels return in English following the refresh in the browser [#3237]
  • Bugfix: AUX Device on com3 was activated by default [#3335]
  • Bugfix: SNMP-Agent appends wrong .0 to OIDs of tabular values [#3341]
  • Bugfix: UNMS gets a network lost when the UPS device is deactivated [#3234]
  • Bugfix: BACS temperature decimal places, alarms present and module type via SNMP [#3299]
  • Bugfix: BACS current sensor display of negative values on monitor screen [#3317]
  • Bugfix (in UNMS software in conjunction with CS141) UNMS BACS Screen shows only 1 Current sensor (#3337)

OEM customer specific features, changes and fixes

  • AEG: New UPS model "Protect PLUS M600", $$MBSALIRM2 [#3304]
  • KESS: New UPS model “BatterX TX301", $$TX301 [#3086]
  • SALICRU: Removed some items from monitor screen for $$MBSALIRM [#2174]
  • BENNING: UPS time sync for UPS models with protocol $$BENMODn [#3353]
    Timeout for $$BENMOD increased (#3349)
  • CENTIEL: UPS Events (History) display (ID: 11) for ##CENTIEL [#3205]
  • PILLER: Monitor screen for "APOTRANS III" [#3357]
  • GENEREX12:SOCOMEC ITIS PRO added