2.06 - 220413

13. April 2022

Security Update

Added Features

  • BACS: Introduce Battery Capacity per Cell/Block Display [T4476]
  • UI for disabling TCP port 4000 [T4340]
  • Extend the MIB file with battery date and expired trap for "battery too old" [T4567]
  • SensorMan, SiteMan, SiteMon: Make Digital IO-Ports available via Modbus [T4650]
  • Add a dedicated field for the eMail subject [T4451]
  • Add 802.1X machine authentication [T4576]
  • "Q5" Impementation for $$PRABLER3 [T4573]

Changed Functionality

  • SiteManager6/SENSORMANAGER: Improvements in the visualizations [T4672]
  • Remove deprecated TLS 1.1 version [T4741]
  • Allow editing of RCCMD broadcast address [T4710]

Bug Fixes

  • Frontend security patches [T4734]
  • BACSLog Chart shows always GMT/UTC+0 Timestamp [T4688]
  • BACSLog Chart Wrong Impedance Value/Scaling at "n.a." Value [T4737]
  • Activation of eMail option "send ... for most important events" leads to empty eMails [T4744]
  • $$MBTAURUS: UPS "On Battery Time" is not incremented [T4709]
  • $$MDELTA: Battery voltage value is output with "n.a" via SNMP and DataLog [T4725]
  • $$MBTAURUS Wrong Energy Consumption Counter [T4718]
  • $$MBTAURUS "UPS Monitor" Screen Loading Extremly Slow [T4717]
  • $$STSABLER: ATS system temperatur value is shown as "n.a." [T4724]
  • UPS "Reset Output Energy Consumption" function fails [T4708]
  • "BACS_GX_AUX" Monitor Link always present at User Guest & Customer [T4693]
  • SNMP SET: Switching of SensorManager outputs not possible [T4670]
  • Fixed API returncode for failures on setting values under devices/bacs/config

OEM customer specific features, changes and fixes

  • OEM 002: Added PROTECT 1 (LCD) with XONL12B2
  • OEM 008: $$TRIMOD: Provision of module data via SNMP [T4514]
  • OEM 012: Added INNOVA Unity IOT 1-20kVA with XONL12B2
  • OEM 012: Added KEHUA UPS as PFLEX
  • OEM 012: Added KEHUA KR33 with MBKELONG
  • OEM 012: Added KEHUA FR-UK33 with PRFLEX
  • OEM 012: Added EAST UPS 3 Phase with MEGA
  • OEM 012: Added 9SX series since 2020 with MGESHUT
  • OEM 012: Added OFYS RT with PREXT
  • OEM 012: Added AMPLON RT Seris with MDELTA
  • OEM 015: Added PowerValue 11Li UP Series with APEX
  • OEM 015: Added PowerValue 11Li PRO Series with PRFLEX
  • OEM 016: Added 9SX series since 2020 with MGESHUT
  • OEM 017: Changed ML-T 800 - 3000 protocol PREXT to ML-800 T - 3000T with PREXT
  • OEM 021: Added OnPower GRT 1-10 and changed autonomytime
  • OEM 025: Added ZIRKON with MBTAURUS protocol
  • OEM 029: Added PowerValue 11Li UP Series with APEX
  • OEM 029: Added PowerValue 11Li PRO Series with PRFLEX
  • OEM 030: $$JBUSDAKER (Amberwave AMB RT/T 1-3 kVA): Panels "Ext. Information" and "Battery" information are overlapping [T4685]
  • OEM 032: Added ADIRA T 1-3 kVA with XONL12B2
  • OEM 032: Implementation Centralion/Eaton Unity Anlagen [T4477]
  • OEM 032: "MD/MDO PRO Series" >= 4,5 kVA ( $$KSTAR / $$KSTAR2 ): Extension for switching the outlets [T4528]
  • OEM 035: Added JOVYFLEX with PRECT
  • OEM 035: Added JOVYSUN with CNETIEL2
  • OEM 035: Added JOVYTEC PE/PME DC36V - 240V with PRFLEX
  • OEM 035: $$EVO (JOVYSTAR e-series): Battery voltage is not displayed [T4702]
  • OEM 036: Added "UPS Internal Fault" T4701 for use with UNMS
  • OEM 036: Added PowerValue 11Li UP Series with APEX
  • OEM 036: Added PowerValue 11Li PRO Series with PRFLEX
  • OEM 036: $$CONCE Output Power (W) via MODBUS not available [T4721]
  • OEM 036: $$CONCE: Add "UPS Internal Fault" Event [T4701]
  • OEM 044: Updated company logo
  • OEM 048: Added SOCOMEC UPS and Transferswitches
  • OEM 048: Added Multi Power (MPX) 15-300 kVA with GPSER
  • OEM 049: Added OFYS RT with PREXT
  • OEM 050: Changed EssentialPower 1-20KVA from PRABLER2 to PRABLER3
  • OEM 050: $$CENTIEL2: Add 'sync time with UPS' functionality [T4695]
  • OEM 050: $$CENTIEL2: Adjust the scaling of L1 Bypass/Output frequency [T4640]
  • OEM 051: Added 2033C,D
  • OEM 051: Added 7011A
  • OEM 051: Added 9800A,AD
  • OEM 051: Added 9900A
  • OEM 051: $$TOSHIBASEC (Mitsubishi 2033C,D): Communication does not start if bypass values are not supported [T4684]
  • OEM 055: Added ITUIS 3 1-10 kVA
  • OEM 055: Added KR1000+ - 3000+ with PRFELX
  • OEM 055: Added UPS5000-E with MBHUAWEI
  • OEM 055: Added OFYS RT with PREXT
  • OEM 058: "Savepower-EVO UPS" 3/1 shows Bypass Voltage L2/L3 [T4484]
  • OEM 059: Changed Company Logo
  • OEM 061: Delta NH+/Delta RT UPS: Serial communication problems with $$MDELTA and $$GEDELTA protocols [T4666]
  • OEM 064: Added Multi Power MPW with GPSER
  • OEM 070: $$EVOGEN ("Type 1") UPS Screen Rectifier LED not working [T4728]
  • OEM 070: $$EVOGEN ("Type 1"): Incorporate enhancements from customers report [T4681]
  • OEM 077: SNG Display "unreachable" in UNMS with CONCE and GPSER fixed
  • OEM 082: Added SLC TWIN RT2 LION with PREXT
  • OEM 082: "SLC CUBE4 <=20kVA": UPS Monitor does not display graphics [T4699]
  • OEM 092: AChanged ZP120LCD-10K-20K protocols from AETSER to XONL12B
  • OEM 099: Added Agpower C RTH 1-10 KVA
  • OEM 099: Added Agpower Bravo RT 1 - 3

2.04 - 211222

22. December 2021

Normal Update

Added Features

  • Log user actions [T4448]
  • Configurable Lograte for UPS DataLog [T4478]
  • SNMP: Add "Redundancy lost" to UPS MIB [T4568]
  • BACS: GX_R_AUX Status via SNMP/MODBUS [T3860]
  • BACS: Introduce Capacity per Cell/Block Display [T4476]
  • "Q5" Impementation for $$PRABLER3 [T4573]
  • Show firmware version in the left menu bar [T4184]

Changed Functionality

  • Improvement of the frontend login process [T4671]
  • Improvement BACS Impedance Threshold Page [T4389]
  • Clarify the usage of the Modbus Slave ID in the frontend [T4621]
  • BACS: Improve the "communication lost" log messages for devices connected to the bus [T4639]
  • Sensormanager Setup: The apply buttons should turn blue after a configuration change [T4359]

Bug Fixes

  • $$AETSER: The UPS status is always "Battery disconnected" [T4678]
    • A regression bug that was introduced with Version 2.04 - 20211215.
  • Minor alignment flaws in the scheduler display [T4563]
  • BACnet "Object Name" is not updated when changed [T4635]
  • Page "System > About" does not show 2nd DNS Server [T4626]
  • Error message on successful synchronization with time server [T4622]
  • BACS: In "Thermal Runaway" configuration the mode for the Battery-Breakers can not be set [T4643]
  • Radius: The Service-Type configured in the Microsoft NPS Server is not recognized [T4645]
  • The requirement "Change password before first usage" is not fulfilled [T4632]
  • With the option "Force HTTPS", the device menu entries are displayed incorrectly [T4651]
  • $$PREXT (EGRT 1,5K / EL01509X11): Manual execution of shutdown/restore command is not logged [T4553]

OEM customer specific features, changes and fixes

  • OEM 002: Implementation of UPS model "Protect Plus S500" [T4470]
  • OEM 002: "Protect D (LCD) 6-10 kVA", $$XONL12D: custom threshold menu is not at present [T4616]
  • OEM 004: Added 3/3 Phase UPS series, $$PREXT based, as XANTO 10000 3/3 - 40000 3/3
  • OEM 008: Added WHAD HE 3000-6000 series, based on $$TRIMOD
  • OEM 008: $$ECONT: WHAD 800-1000-1500-2000-2500-CAB [T4467]
  • OEM 008: $$KEORSP: KEOR SP [T4464]
  • OEM 008: $$ECONT2: Megaline [T4466]
  • OEM 008: $$CYBER3: KEOR PDU [T4463]
  • OEM 008: $$JBUSDAKER:: Daker DK Plus (single phase) [T4460]
  • OEM 008: $$PRABLER2 / $$PRABLER: Keor Line RT - Niky - Niky S [T4461]
  • OEM 008: $$PRABLER2: Keor LP - Keor S - Daker DK (single phase) [T4462]
  • OEM 008: $$PRFLEX31: Daker DK 10000 (three phase) - Daker DK Plus 10000 (three phase) [T4459]
  • OEM 009: Reorganized UPS Modellist
  • OEM 012: Added JBUS Statys STS
  • OEM 012: Added DK Plus series, based on $$JBUSDAKER
  • OEM 028: Email trap pre-configuration [T4633]
  • OEM 032: "Triton 10-500 kVA ext.port": Special Current Value Multiplier for BVG [T4519]
  • OEM 032: "MD/MDO PRO Series" <= 3 kVA : Add USB & MODBUS KSTAR protocol (slot) [T4527]
  • OEM 032: "MD/MDO PRO Series" >= 4,5 kVA ( $$KSTAR / $$KSTAR2 ): Extension for switching the outlets [T4528]
  • OEM 032: $$PREXT (EFFEKTA MTX 1500): Displayed serial number consists of zeros only [T4561]
  • OEM 035: Added JovySky M and L series, based on $$MBTAURUS
  • OEM 036: DataLog Chart: Selection of months and start date is not possible [T4452]
  • OEM 044: First OEM Release with UPS series Taurus, Kronos, Mars, Ares, Odin, Titan and Transferswitch ATS
  • OEM 048: Added Multi Power MPW, based on $$GPSER
  • OEM 050: $$CENTIEL Improvement Battery Current [T4631]
  • OEM 050: $$CENTIEL2: Temperature handling for invalid values [T4642]
  • OEM 051: $$MITSUBISHI_SEC (Mitsubishi 9900B): Incorrect SNMP displaying of Info and Inverter Status [T4656]
  • OEM 055: Added ITYS 3, XTREME P90 and P91 series
  • OEM 060: Fixed SNMP section for $$MDELTA and adjusted battery voltage for C series
  • OEM 062: $$KLEIN1 "Parser Error" at UPS History Download [T4646]
  • OEM 066: Added APC, MGE, DELTA and ITYS 1000-10000VA series
  • OEM 070: "Device Type 1" Register Extension [T4575]
  • OEM 070: "Device Type 1" ($$EVOGEN): Modification UPS History Reading [T4637]
  • OEM 070: UPS Type 16 ($$EVO16): UPS screen is not displayed if UPS name contains non-ASCII characters [T4629]
  • OEM 070: "UPS Type 16/17/18", $$EVO16/17/18, MOD_EVO3, Modbus addresses 200 to 599 are not implemented [T4625]
  • OEM 095: $$EVO2, (S5300X EVO): Serial communication on/off problems [T4662]

2.02 - 210930

30. September 2021

Important Update

After upgrading to this firmware version, it is no longer possible to downgrade to a lower version.

Added Features

  • User authentication using RADIUS [T566]
  • Introduce 'BACSKIT LC' series as new HW-Platform [T4542]
  • BACS Threshold "Current Difference between Strings" [T4116]
  • Include OEM specific favicon's [T4364]
  • Enable configuration of user names [T4453]
  • Introduce SNMP Test Traps for all devices [T4383]
  • Show UPS serial number in the UPS screen, if available [T4418]
  • Custom Threshold Extension Output Power/Output Load [T4410]

Changed Functionality

  • Page title changed from “CS141 Webmanager” to generic “Web Manager” [T4580]
  • Improved Company/OEM Logo, in the upper left corner of every Webpage.
  • BACS: Improve tooltip for option to Display 2 jars per module [T4366]
  • Verification of an uploaded web server TLS certificate [T4449]
  • Allow SNMP community without IP restrictions [T4436]

Bug Fixes

  • Hotfix for prior 2.02 release: “BACS E-Mail Traps may not work without GX_R_AUX” [T4578]
  • BACS Programmer Single Adressing Mode may show "failed" [T4532]
  • With option "Force HTTPS" the automatic redirection from http to https may not work [T4483]
  • GPIO: Initialize boot option and rescue pins correctly [T358]
  • At GX_R_AUX email traps generate an error [T4538]
  • After backup/restore, an upload of the server certificate is no longer possible [T4513]
  • Variable #AUTONOMTIME does not decrease during a powerfail [T4521]
  • Not possible to enter a host name for the model "SNMP UPS RFC1628 compliant" [T4472]
  • SNMPv3: The value of snmpEngineBoots is not incremented [T4520]
  • $$GPSER: Output Power Values "0" (W/VA) at 19% Load [T4487]
  • CON_R_AUX4 outputs and SENSORMANAGER outputs interfer when both devices are connected [T4198]
  • After Reboot, Rsyslog does not show the host name [T4421]
  • "SNMP UPS-RFC 1628 compliant" model = its not possible to execute a UPS test [T4422]
  • The job AUX is not available for sensormanager outputs when a BACS GXR__AUX is configured [T4197]

OEM customer specific features, changes and fixes

  • OEM 001: LEGACY version received all OPTI and CYBERPOWER UPS models
  • OEM 002: AEG added "Protect 1 (LCD)" with XONL12B
  • OEM 002: Modbus Extension AEG "Protect 8.33" [T4570]
  • OEM 003: Missing UPS History XSL File in Email attachment [T4413]
  • OEM 003: PILLER added model "AR COMFORT+"
  • OEM 004: $$PREXTXANTO (XANTO 6000 + 1Batt (Mod.2017)): Add load in percent to the UPS screen [T4540]
  • OEM 004: Xanto S 1500 (Mod.12), $$XONL12A, "Restart the UPS" button/function is not at present in the UPS Functions [T4427]
  • OEM 008: $$TRIMOD (RATP version), $$TRIMOD, all MODBUS values are zero [T4350]
  • OEM 012: GENEREX NEUTRAL added THOR ELMOD series
  • OEM 017: MULTIMATIC added "Riello Sentinel Dual SDU series"
  • OEM 022: BORRI added Galileo T/RT 1-10kVA,Leonardo T/RT 6 and 10kVA with PRABLER2
  • OEM 022: BORRI added Ingenio compact 10-20kVA with MBTAURUS
  • OEM 025: Email trap pre-configuration [T4315]
  • OEM 025: $$MBTAURUS: Wrong Output Energy Counter Calculation [T4482]
  • OEM 028: $$MBTAURUS (KRONOS 10 kVA): Add values for pos./neg. battery discharge currents [T4480]
  • OEM 028: AKKUTRONIK UPS modellist sorted new and older models moved to the LEGACY section
  • OEM 031: ALLNET added "All910019RT USB","All915019RT USB","All920019RT USB","All930019RT USB" with AEGSER
  • OEM 032: EFFEKTA added models "MD-1000-3000 PRO"
  • OEM 032: EFFEKTA cross added models "MD-4500-10000 PRO"
  • OEM 034: SCHNEIDER-ELECTRIC received FAVICON for all Webserver based products
  • OEM 035: JOVYATLAS changed UPS modelist (sorting and name adjustments)
  • OEM 036: $$CONCE: Event for the user-defined threshold alarm " Battery autonomy" could jump back and forth [T4562]
  • OEM 036: $$CONCE: Full Test runs too short via UPS functions [T4231]
  • OEM 036: $$CONCE: Provision of module data via Modbus [T4535]
  • OEM 036: ABB added "POWERVALUE 11T G2 1-10kVA" with Protocoll PREXT
  • OEM 036: ABB added "POWERVALUE 11T G2 1-10kVA" with Protocoll PREXT
  • OEM 036: ABB changed CONCE Modbus output INFREQ and BY_FREQ to integer [T4523]
  • OEM 042: COMPUPOWER SOUTH AFRICA added "Compower Micro 1 -10 kVA" using PRABLER2
  • OEM 050: $$CENTIEL(2): Modbus Extension [T4531]
  • OEM 050: $$CENTIEL(2): Massive memory loss after 7 days uptime [T4469]
  • OEM 050: $$CENTIEL(2): Provide UPS version, serial and id via Modbus [T4426]
  • OEM 050: $$CENTIEL(2): UPS Alert History: The order of CS141 and UPS display is different [T4324]
  • OEM 050: $$CENTIEL(2): UPS variables are not set correctly in email [T4454]
  • OEM 050: $$CENTIEL2: BypassBad and FanFailure are not reported to system module [T4526]
  • OEM 050: $$CENTIEL2: Power failure is sometimes not reported to system module [T4525]
  • OEM 050: CENTIEL added EssentialPower 1-20kVA
  • OEM 051: Remove UPS functions and add back custom thresholds [T4388]
  • OEM 052: First Firmware for new OEM ELIT added UPS NS & SR series 1-20 kVA
  • OEM 058: $$GPSER (SIEL UPS Safepower EVO HF): Status "batteries are disconnected" is not detected [T4473]
  • OEM 058: SIEL added "SIEL UPS Safepower EVO HF" with GPSER
  • OEM 058: SIEL added "SIEL UPS Safepower EVO HFT" with SENT2
  • OEM 058: SIEL removed UPS OFF command for Safepower EVO HF
  • OEM 058: SIEL Safepower EVO HF added "batteries are disconnected"for GPSER thru workaround - battery test results as "failed" if battery is disconnected.
  • OEM 066: AKI added APC, MGE, DELTA series
  • OEM 070: Implementation of new "Device Type 1" [T4407]
  • OEM 082: Implementation of new "SLC ADAPT2" Serie [T4316]
  • OEM 084: KOHLER added "PowerWAVE ELMOD Series"
  • OEM 085: IBR SAUDI ARABIA first Firmware release
  • OEM 087: $$MBSALIRM(HiUp series): UPS screen corrections [T4406]
  • OEM 087: $$MDELTA (Midi J D): No alarm in case of defective module [T4166]
  • OEM 087: ADPOS changed "Maxi J I series" using MBSALIRM to MBSALIRM3
  • OEM 099: AGIT added "Agpower RMY and ETC series with KSTAR2
  • OEM 099: AGIT added Agpower RMY and ETX series with MEGAE