Added Features
- Allow multiple receivers in E-Mail configuration [T3790]
- UPS communication now configurable either via COM1 RS232 or alternatively via RS485 COM2 [T3686]
- BACS Scheduler Job added sending logfiles by eMail [T3736]
- Interval change at scheduled tasks added, interval "yearly" added [T3748]
Changed Functionality
- BACS delays alarms for Impedance-Out-Of-Upper-Range [T3734]
Bug Fixes
- UNMS: BACS Status shows "unreachable" with FW 1.76-190214 [T3761]
- Fix for delay event configuration at Sitemanager 6 for outputs 5-8 [T3531]
- Updated SNMP library (net-snmp) to version 5.8 [T3653]
- Fix for BACS display 2 Mio. deg. Fahrenheit at a disscharge [T3777]
- Regression bugfix since 1.77: Scheduler SMS Job phone number input not possible
- Regression bugfix since 1.77: Existing scheduler interval configuration lost after update
- Regression bugfix since 1.77: SNMP "No such Object" for BACS OID's if UPS is disabled [T3786]
- Regression bugfix for DELTA UPS modular Screen [T3744]
- DELTA Ultron DPS series temperature N/A fixed [T3756]
- Webserver hangs if changing the default monitor page [T3787]
- BACS AC Ripple value must not be used for Discharge Detection [T3783]
- Email Traps fix - Counterevents now used for cancle alarm conditions [T3747]
- BACS shows "Error HW Revision/Calibration mismatch" on discharge [T3782]
- BACS discharge thresholds defaults to a maximum of -15amps [T3727]
- Port forwarding causes broken links to devices 'monitor' pages [T3332]
- Disabling "Automatic Logout" generates "Server Error (-1)" [T3697]
- CON_AUX4 & CON_R_AUX4 configuration bugfix [T3716]
- Multiple Eventconfiguration / Email Subject bugfix [T3614]
- At BACKUP the timezone could not be restored [T3739]
OEM customer specific features, changes and fixes
- OEM 002: New AEG Protect A (LCD) implemented [T3657]
- OEM 003: PILLER APOCONV AC 100 Screen changes
- OEM 003: PILLER changed values for datalog for various UPS models
- OEM 004: XANTO S 1000 shows capacity value with disconnected batteries [T3753]
- OEM 008: MEGALINE UPS $$ECONT2 Screenbugfixes in the UPS Events History [T3745]
- OEM 012: Added DELTA "EH" Series $$MDELTA [T3714]
- OEM 012: Added "Socomec MASTERYS GP4" with JBUSMODULYS
- OEM 017: Added ABLEREX USV 3rd generation PRABLER3 to Multimatic modellist as ML-xxxxI series
- OEM 017: Added "Socomec MASTERYS GP4" with JBUSMODULYS
- OEM 021: ERREPI Added NP10SR-NP30SR series
- OEM 022: Integration of new UPS Type 15 [T3780]
- OEM 022: $$EVO: Add SNMP values for upsConfig variables [T3773]
- OEM 026: CTA added "Socomec MASTERYS GP4" with JBUSMODULYS
- OEm 028: AKKUTRONIK added "Socomec MASTERYS GP4" with JBUSMODULYS
- OEM 030: UPS SERVIS added "Amberwave AMB3300PRO 10-20k"
- OEM 032: EFFEKTA FULLTEST changed for MTD 1000XL RT - 3000 XL RT series. At a load change the system will ask - the user to restart the FULLTEST
- OEM 050: CENTIEL Fixed Bad Input Frequency on the DataLog [T3733]
- OEM 050: CENTIEL added SNMP MIB objects [T3732]
- OEM 045: Implementation of Nextys DC UPS via RS485 for Woehrle [T3682]
- OEM 047: S2S added "Socomec MASTERYS GP4" with JBUSMODULYS
- OEM 055: COROMATIC Added "Socomec MASTERYS GP4" with JBUSMODULYS
- OEM 058: SIEL adds 'Input Auxiliary' status bits to all SIEL_TRAPMSG [T3711]
- OEM 064: LEISTUING Brasil added "Socomec MASTERYS GP4" with JBUSMODULYS
- OEM 067: COMPUPOWER South Africa added "Socomec MASTERYS GP4" with JBUSMODULYS
- OEM 077: SNG Australia added "Socomec MASTERYS GP4" with JBUSMODULYS
- OEM 082: SALICRU changes color scheme from blue to red. First version using red color [T3687]
- OEM 082: Salicru RM Modbus uses now a not GENEREX standard Modbus mapping
- OEM 087: ADPOS changes on "Ultron DPS 60-400 kVA" $$MDELTA [T3714]
- OEM 088: ENERSYS added "Socomec MASTERYS GP4" with JBUSMODULYS
- OEM 096: BJ BALFOUR China added "Socomec MASTERYS GP4" with JBUSMODULYS