After upgrading to this firmware version, it is no longer possible to downgrade to a lower version.
Added Features
- User authentication using RADIUS [T566]
- Introduce 'BACSKIT LC' series as new HW-Platform [T4542]
- BACS Threshold "Current Difference between Strings" [T4116]
- Include OEM specific favicon's [T4364]
- Enable configuration of user names [T4453]
- Introduce SNMP Test Traps for all devices [T4383]
- Show UPS serial number in the UPS screen, if available [T4418]
- Custom Threshold Extension Output Power/Output Load [T4410]
Changed Functionality
- Page title changed from “CS141 Webmanager” to generic “Web Manager” [T4580]
- Improved Company/OEM Logo, in the upper left corner of every Webpage.
- BACS: Improve tooltip for option to Display 2 jars per module [T4366]
- Verification of an uploaded web server TLS certificate [T4449]
- Allow SNMP community without IP restrictions [T4436]
Bug Fixes
- Hotfix for prior 2.02 release: “BACS E-Mail Traps may not work without GX_R_AUX” [T4578]
- BACS Programmer Single Adressing Mode may show "failed" [T4532]
- With option "Force HTTPS" the automatic redirection from http to https may not work [T4483]
- GPIO: Initialize boot option and rescue pins correctly [T358]
- At GX_R_AUX email traps generate an error [T4538]
- After backup/restore, an upload of the server certificate is no longer possible [T4513]
- Variable #AUTONOMTIME does not decrease during a powerfail [T4521]
- Not possible to enter a host name for the model "SNMP UPS RFC1628 compliant" [T4472]
- SNMPv3: The value of snmpEngineBoots is not incremented [T4520]
- $$GPSER: Output Power Values "0" (W/VA) at 19% Load [T4487]
- CON_R_AUX4 outputs and SENSORMANAGER outputs interfer when both devices are connected [T4198]
- After Reboot, Rsyslog does not show the host name [T4421]
- "SNMP UPS-RFC 1628 compliant" model = its not possible to execute a UPS test [T4422]
- The job AUX is not available for sensormanager outputs when a BACS GXR__AUX is configured [T4197]
OEM customer specific features, changes and fixes
- OEM 001: LEGACY version received all OPTI and CYBERPOWER UPS models
- OEM 002: AEG added "Protect 1 (LCD)" with XONL12B
- OEM 002: Modbus Extension AEG "Protect 8.33" [T4570]
- OEM 003: Missing UPS History XSL File in Email attachment [T4413]
- OEM 003: PILLER added model "AR COMFORT+"
- OEM 004: $$PREXTXANTO (XANTO 6000 + 1Batt (Mod.2017)): Add load in percent to the UPS screen [T4540]
- OEM 004: Xanto S 1500 (Mod.12), $$XONL12A, "Restart the UPS" button/function is not at present in the UPS Functions [T4427]
- OEM 008: $$TRIMOD (RATP version), $$TRIMOD, all MODBUS values are zero [T4350]
- OEM 012: GENEREX NEUTRAL added THOR ELMOD series
- OEM 017: MULTIMATIC added "Riello Sentinel Dual SDU series"
- OEM 022: BORRI added Galileo T/RT 1-10kVA,Leonardo T/RT 6 and 10kVA with PRABLER2
- OEM 022: BORRI added Ingenio compact 10-20kVA with MBTAURUS
- OEM 025: Email trap pre-configuration [T4315]
- OEM 025: $$MBTAURUS: Wrong Output Energy Counter Calculation [T4482]
- OEM 028: $$MBTAURUS (KRONOS 10 kVA): Add values for pos./neg. battery discharge currents [T4480]
- OEM 028: AKKUTRONIK UPS modellist sorted new and older models moved to the LEGACY section
- OEM 031: ALLNET added "All910019RT USB","All915019RT USB","All920019RT USB","All930019RT USB" with AEGSER
- OEM 032: EFFEKTA added models "MD-1000-3000 PRO"
- OEM 032: EFFEKTA cross added models "MD-4500-10000 PRO"
- OEM 034: SCHNEIDER-ELECTRIC received FAVICON for all Webserver based products
- OEM 035: JOVYATLAS changed UPS modelist (sorting and name adjustments)
- OEM 036: $$CONCE: Event for the user-defined threshold alarm " Battery autonomy" could jump back and forth [T4562]
- OEM 036: $$CONCE: Full Test runs too short via UPS functions [T4231]
- OEM 036: $$CONCE: Provision of module data via Modbus [T4535]
- OEM 036: ABB added "POWERVALUE 11T G2 1-10kVA" with Protocoll PREXT
- OEM 036: ABB added "POWERVALUE 11T G2 1-10kVA" with Protocoll PREXT
- OEM 036: ABB changed CONCE Modbus output INFREQ and BY_FREQ to integer [T4523]
- OEM 042: COMPUPOWER SOUTH AFRICA added "Compower Micro 1 -10 kVA" using PRABLER2
- OEM 050: $$CENTIEL(2): Modbus Extension [T4531]
- OEM 050: $$CENTIEL(2): Massive memory loss after 7 days uptime [T4469]
- OEM 050: $$CENTIEL(2): Provide UPS version, serial and id via Modbus [T4426]
- OEM 050: $$CENTIEL(2): UPS Alert History: The order of CS141 and UPS display is different [T4324]
- OEM 050: $$CENTIEL(2): UPS variables are not set correctly in email [T4454]
- OEM 050: $$CENTIEL2: BypassBad and FanFailure are not reported to system module [T4526]
- OEM 050: $$CENTIEL2: Power failure is sometimes not reported to system module [T4525]
- OEM 050: CENTIEL added EssentialPower 1-20kVA
- OEM 051: Remove UPS functions and add back custom thresholds [T4388]
- OEM 052: First Firmware for new OEM ELIT added UPS NS & SR series 1-20 kVA
- OEM 058: $$GPSER (SIEL UPS Safepower EVO HF): Status "batteries are disconnected" is not detected [T4473]
- OEM 058: SIEL added "SIEL UPS Safepower EVO HF" with GPSER
- OEM 058: SIEL added "SIEL UPS Safepower EVO HFT" with SENT2
- OEM 058: SIEL removed UPS OFF command for Safepower EVO HF
- OEM 058: SIEL Safepower EVO HF added "batteries are disconnected"for GPSER thru workaround - battery test results as "failed" if battery is disconnected.
- OEM 066: AKI added APC, MGE, DELTA series
- OEM 070: Implementation of new "Device Type 1" [T4407]
- OEM 082: Implementation of new "SLC ADAPT2" Serie [T4316]
- OEM 084: KOHLER added "PowerWAVE ELMOD Series"
- OEM 085: IBR SAUDI ARABIA first Firmware release
- OEM 087: $$MBSALIRM(HiUp series): UPS screen corrections [T4406]
- OEM 087: $$MDELTA (Midi J D): No alarm in case of defective module [T4166]
- OEM 087: ADPOS changed "Maxi J I series" using MBSALIRM to MBSALIRM3
- OEM 099: AGIT added "Agpower RMY and ETC series with KSTAR2
- OEM 099: AGIT added Agpower RMY and ETX series with MEGAE